Short tests in which the participant holds the phone still, with the hand resting and with the arm outstretched; the phone's accelerometer measures tremor.
Configure parameters and run an interactive preview exactly as participants will experience it. No data is recorded.
Adjust parameters below, then start the preview on the right.
Include practice trials
Shown with feedback before the main task
Task parameters
BetaBeing checked on iOS and Android devices.
Phones only: the task records the phone's motion sensors. The phone vibrates at the start and end of each recording, and the screen stays on. The web preview shows the screens without measuring.
Seated, eyes closed, the phone in the palm with the forearm on the thigh (rest), then in the outstretched hand, palm up (postural). Not a diagnostic test (Lipsmeier et al., 2022).
Default both (Lipsmeier et al., 2022).
Default left (not stated in the source).
10–60. Default 15 per hand (Lipsmeier et al., 2022; the 2018 version used 30 s).
Default 5 (no published value).
4 tests × 15 s (about 2 min).
Outputs per test and hand: the log median squared energy, log(median(ax² + ay² + az²)) (Lipsmeier et al., 2022; with gravity removed, and also with it, since the source does not say); tremor power between 2 and 10 Hz and the dominant frequency, from the magnitude of the acceleration, √(x² + y² + z²), high-passed at 2 Hz and resampled to 50 Hz (Kassavetis et al., 2016). Each recording starts 0.5 s after the start vibration (no published value).
This is a researcher preview. No participant data is recorded.
Simulated participant view
Short tests in which the participant holds the phone still, with the hand resting and with the arm outstretched; the phone's accelerometer measures tremor.
No data is recorded
Phones only. Seated, eyes closed, the participant holds the phone in the palm with the forearm resting on the thigh (rest tremor), then in the outstretched hand, palm up (postural tremor), 15 seconds per hand, counting down out loud from a number shown before each test. A vibration marks the start and the end of each recording. The web preview shows the screens only.
Useful for frequent, remote tremor measurement in Parkinson's disease, essential tremor and medication studies, where change over repeated tests and differences between the hands matter.
Not a diagnostic test and not a replacement for a clinical tremor rating: correlations with the MDS-UPDRS tremor items ranged from .23 to .71 (Lipsmeier et al., 2022). The weight of a phone held in the outstretched hand affects the arm's movement, which may weaken postural-tremor measures (Kostikis et al., 2015). Beta: being checked on iOS and Android devices.
The defaults follow the rest and postural tremor tests of the Roche PD Mobile Application v2 (Lipsmeier et al., 2022): seated, eyes closed, the phone in the palm with the forearm on the thigh, then in the outstretched hand, counting down aloud from a number that changes each time, 15 s per hand. The palm faces up in the postural test as in the first version of the app (Lipsmeier et al., 2018). Plan repeated tests: Lipsmeier et al. summarized tests over 2 weeks.
Higher values mean more tremor. Test-retest ICCs of the log median squared energy were .83–.94, higher on the more affected side, and its correlation with the MDS-UPDRS tremor items was strongest on the more affected side (rest ρ = .71, postural ρ = .50; Lipsmeier et al., 2022). Tremor power correlated with clinical rest (r = .60) and postural (r = .65) tremor ratings in a small sample (n = 14; Kassavetis et al., 2016). Lipsmeier et al. excluded tests with the phone on a table but publish no rule; this task does not flag them.
Add Rest and Postural Tremor to your ESM study on SMAAT — free to get started.